Call Us +91 9311082008

cncautomations-product

Safety foot-switch, single pedal

Safety foot pedal FE-FS1-SU1ASDU1-U-XX

The foot pedal FE-FS1-SU1ASDU1-U have 3 positions with a pressure point, to control dangerous movements (for instance get down of a press brake ect ). It has 2 working contacts ( 1NC+1NO) to drive the movement and one safety switches (1 positive opening NC contact + 1NO) to stop the movement.

Pressing the foot pedal, till the pressure point, allows the changeover of the 2 working contacts. Once the pressure point is got over, the 2 working contacts return to their first position and the positive opening safety contact is activated in order to initiate immediately the dangerous movement. Thus a redundant information for the safety circuit is available.

A restart of the machine is only possible after releasing the foot switch.

Safety foot pedal FE-FS1-SU1ASDO2V-U-XX

The foot pedal FE-FS1-SU1ASDO2V-U have 3 positions with a pressure point and a pedal lock with manual re- lease, to control dangerous movements (for instance get down of a press brake ect ). It has 2 working contacts (1NO and 1NC) to drive the movement and one safety switches (2 positive opening NC contacts)to stop the movement.

Pressing the foot pedal, till the pressure point, allows the changeover of the 2 working contacts. Once the pressure point is got over, the 2 working contacts return to their first position and the positive opening safety contact is activated in order to initiate immediately the dangerous movement. Thus a redundant information for the safety circuit is available.

A restart of the machine is only possible after releasing the foot switch.

Safety foot pedal FE-FS1-S2DO2V-U-XX

The foot pedal FE-FS1-SU1ASDU1-U have 3 positions with a pressure point, to control dangerous movements (for instance get down of a press brake ect ). It has 2 working contacts ( 1NC+1NO) to drive the movement and one safety switches (1 positive opening NC contact + 1NO) to stop the movement.

Thus a redundant information for the safety circuit is available. A restart of the machine is only possible after releasing the foot switch.

Safety foot-switch, double pedal

Safety foot pedal FE-FS2-SU1ASDU1/U1-U-XX

The safety foot pedal FE-FS2-SU1ASDU1/U1-U use safety switches. The right foot pedal have two positions (free position and pressed down position). It may e.g. be used for the selection of AKAS® Box bending function or opening of a press. The left foot pedal have 3 positions, with a pressure point, to control dangerous movements (for instance get down of a press brake ect).

It has 2 working contacts ( 1NC+1NO) to drive the movement and one safety switch (1 positive opening NC contact + 1NO) to stop the movement. Pressing the foot pedal, till the pressure point, allows the changeover of the 2 working contacts. Once the pressure point is got over, the 2 working contacts return to their first position and the positive opening safety contact is activated in order to initiate immediately the dangerous movement.Thus a redundant information for the safety circuit is available. A restart of the machine is only possible after releasing the foot switch.

Safety foot pedal FE-FS2-U1/SU1ASDU1-U-XX

The safety foot pedal FE-FS2-U1/SU1ASDU1-U use safety switches. The left foot pedal have two positions (free position and pressed down position). It may e.g. be used for the selection of AKAS® Box bending function or opening of a press. The right foot pedal have 3 positions, with a pressure point, to control dangerous movements (for instance get down of a press brake ect).

It has 2 working contacts ( 1NC+1NO) to drive the movement and one safety switch (1 positive opening NC contact + 1NO) to stop the movement. Pressing the foot pedal, till the pressure point, allows the changeover of the 2 working contacts. Once the pressure point is got over, the 2 working contacts return to their first position and the positive opening safety contact is activated in order to initiate immediately the dangerous movement.Thus a redundant information for the safety circuit is available.

A restart of the machine is only possible after releasing the foot switch.

Safety foot pedal FE-FS2-S2ASDO2/U1-U-XX

The safety foot pedal FE-FS2-S2ASDO2/U1-U use safety switches. The right foot pedal have two positions (free position and pressed down position). It may e.g. be used for the selection of AKAS® Box bending function or opening of a press. The left foot pedal have 3 positions, with a pressure point, to control dangerous movements (for instance get down of a press brake ect).

It has 2 working contacts ( 2NO) to drive the movement and one safety switch (2 positive opening NC contact ) to stop the movement. Pressing the foot pedal, till the pressure point, allows the changeover of the 2 working contacts. Once the pressure point is got over, the 2 working contacts return to their first position and the positive opening safety contact is activated in order to initiate immediately the dangerous movement.Thus a redundant information for the safety circuit is available.

A restart of the machine is only possible after releasing the foot switch.

call usnow

+91-9311082008